Vertical
Analysis LLC
6801 Marlboro
Pike
Forestville
Maryland 20747
1(800)447-3344
|
|
|
|
 |
|
|
 |
 |
|
The Step Deflection
test is performed on both sides of the escalator with a load applied to
the step. This test accurately measures the vertical position of the step
tread relative to the bottom of the comb fingers. Measurements are made
to a resolution of 0.1mm (0.004”), at a rate of 60 per second. This data
is used to generate detailed step profile graphs.
This test provides an accurate
indication of the following:
-
Cracked Steps
-
Cracked ‘A’ frames
-
Worn (or soft)
step and axle rollers
-
Worn (or soft) axle bushings
-
Insufficient step & comb mesh
-
Compliance with Local / National
codes and OEM spec’s
Safety is enhanced by:
-
Reducing the potential for combplate
entrapments
-
Reducing the potential for falls
resulting from the unnecessary activation
of the step level device
|
|