Dynamic speed tests
are performed on the Step and Handrail simultaneously. This guages the
relationship of speed transients between the step and the handrail. Measurements
are made to a resolution of 0.1ft/min, at a rate of 30 per second. The
data is used to generate detailed speed profile
graphs.
This test provides an accurate
indication of the following:
-
Stretched / worn chains
-
Worn sprockets
-
Step drive problems
-
Handrail drive problems
-
Compliance with Local / National
codes and OEM spec’s
Safety is enhanced by:
-
Reducing the potential for falls
resulting from the unnecessary activation of the broken / slack step chain
device, broken drive chain device, or the handrail speed monitoring device.
|
|